188 research outputs found

    Information and Beliefs in a Repeated Normal-Form Game

    Get PDF
    We study beliefs and choices in a repeated normal-form game. In addition to a baseline treatment with common knowledge of the game structure and feedback about choices in the previous period, we run treatments (i) without feedback about previous play, (ii) with no information about the opponent’s payoffs and (iii) with random matching. Using Stahl and Wilson’s (1995) model of limited strategic reasoning, we classify behavior with regard to its strategic sophistication and consider its development over time. We use belief statements to check for the consistency of subjects’ actions with the stated beliefs as well as for the accuracy of their beliefs (relative to the opponent’s true choice). In the baseline treatment we observe more sophisticated play as well as more accurate beliefs and more best responses to beliefs over time. We isolate feedback as the main driving force of learning to play strategically and to form beliefs that accurately predict the behavior of the opponent.beliefs, experiments, strategic uncertainty, learning

    Giant nonlocality in nearly compensated 2D semimetals

    Full text link
    In compensated two-component systems in confined, two-dimensional geometries, nonlocal response may appear due to external magnetic field. Within a phenomenological two-fluid framework, we demonstrate the evolution of charge flow profiles and the emergence of a giant nonlocal pattern dominating charge transport in magnetic field. Applying our approach to the specific case of intrinsic graphene, we suggest a simple physical explanation for the experimental observation of giant nonlocality. Our results provide an intuitive way to predict the outcome of future experiments exploring the rich physics of many-body electron systems in confined geometries as well as to design possible applications.Comment: 5 pages, 5 figure

    Stability and relapse after orthodontic treatment of deep bite cases—a long-term follow-up study

    Get PDF
    The purpose of this long-term follow-up study was twofold—firstly, to assess prevalence of relapse after treatment of deep bite malocclusion and secondly, to identify risk factors that predispose patients with deep bite malocclusion to relapse. Sixty-one former patients with overbite more than 50% incisor overlap before treatment were successfully recalled. Clinical data, morphometrical measurements on plaster casts before treatment, after treatment and at long-term follow-up, as well as cephalometric measurements before and after treatment were collected. The median follow-up period was 11.9 years. Patients were treated by various treatment modalities, and the majority of patients received at least a lower fixed retainer and an upper removable bite plate during retention. Relapse was defined as increase in incisor overlap from below 50% after treatment to equal or more than 50% incisor overlap at long-term follow-up. Ten per cent of the patients showed relapse to equal or larger than 50% incisor overlap, and their amount of overbite increase was low. Among all cases with deep bite at follow-up, gingival contact and palatal impingement were more prevalent in partially corrected noncompliant cases than in relapse cases. In this sample, prevalence and amount of relapse were too low to identify risk factors of relaps

    Automated universal chip platform for fluorescence based cellular assays

    Get PDF
    Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich.This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.The advantage of cell based assays used as biosensors is the direct access to hardly obtainable parameters like toxicity, mutagenicity and pharmacological effectiveness. Within the last few years we established a micro fluidic platform including a peristaltic micro pump as well as several valves, manifolds and micro channels [1]. For optical online monitoring the micro fluidic system is bonded to a glass slide. Furthermore the biochip is fixed on an electrically heated support. The pneumatically actuated peristaltic pump as well as the temperature control is performed by a control device. For the fluorescence based online monitoring a robotic guided fluorescence measurement module was developed, which supports the detection of fluorescence in microtiter plates and microfluidic systems. This measurement module allows the fluorescence detection of two different excitation / detection wavelengths (480 / 530 nm and 570 / 620 nm) and was successfully characterised using EGFP and Rhodamine 6G. Additionally three cell based assays with bacterial, yeast and human cells were characterized

    Biosensing platform combining label-free and labelled analysis using Bloch surface waves

    Get PDF
    Bloch surface waves (BSW) propagating at the boundary of truncated photonic crystals (1D-PC) have emerged as an attractive approach for label-free sensing in plasmon-like sensor configurations. Due to the very low losses in such dielectric thin film stacks, BSW feature very low angular resonance widths compared to the surface plasmon resonance (SPR) case. Besides label-free operation, the large field enhancement and the absence of quenching allow utilizing BSW coupled fluorescence detection to additionally sense the presence of fluorescent labels. This approach can be adapted to the case of angularly resolved resonance detection, thus giving rise to a combined label-free / labelled biosensor platform. It features a parallel analysis of multiple spots arranged as a one-dimensional array inside a microfluidic channel of a disposable chip. Application of such a combined biosensing approach to the detection of the Angiopoietin-2 cancer biomarker in buffer solutions is reported

    Correlation energy of an electron gas in strong magnetic fields at high densities

    Full text link
    The high-density electron gas in a strong magnetic field B and at zero temperature is investigated. The quantum strong-field limit is considered in which only the lowest Landau level is occupied. It is shown that the perturbation series of the ground-state energy can be represented in analogy to the Gell-Mann Brueckner expression of the ground-state energy of the field-free electron gas. The role of the expansion parameter is taken by r_B= (2/3 \pi^2) (B/m^2) (\hbar r_s /e)^3 instead of the field-free Gell-Mann Brueckner parameter r_s. The perturbation series is given exactly up to o(r_B) for the case of a small filling factor for the lowest Landau level.Comment: 10 pages, Accepted for publication in Phys.Rev.

    Ultrafast transmission electron microscopy using a laser-driven field emitter: Femtosecond resolution with a high coherence electron beam

    Get PDF
    We present the development of the first ultrafast transmission electron microscope (UTEM) driven by localized photoemission from a field emitter cathode. We describe the implementation of the instrument, the photoemitter concept and the quantitative electron beam parameters achieved. Establishing a new source for ultrafast TEM, the Göttingen UTEM employs nano-localized linear photoemission from a Schottky emitter, which enables operation with freely tunable temporal structure, from continuous wave to femtosecond pulsed mode. Using this emission mechanism, we achieve record pulse properties in ultrafast electron microscopy of 9 Å focused beam diameter, 200 fs pulse duration and 0.6 eV energy width. We illustrate the possibility to conduct ultrafast imaging, diffraction, holography and spectroscopy with this instrument and also discuss opportunities to harness quantum coherent interactions between intense laser fields and free-electron beams

    Label-free and fluorescence biosensing platform using one dimensional photonic crystal chips

    No full text
    The increasing demand for early detection of diseases drives the efforts to develop more and more sensitive techniques to detect biomarkers in extremely low concentrations. Electromagnetic modes at the surface of one dimensional photonic crystals, usually called Bloch surface waves, were demonstrated to enhance the resolution and constitute an attractive alternative to surface plasmon polariton optical biosensors. We report on the development of Bloch surface wave biochips operating in both label-free and fluorescence modes and demonstrate their use in ovalbumin recognition assays
    • …
    corecore